Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1954 1
1957 1
1962 1
1966 2
1971 1
1972 1
1973 1
1974 1
1975 4
1976 6
1977 2
1978 1
1979 3
1980 2
1981 1
1982 1
1983 3
1984 1
1985 1
1987 1
1988 3
1989 5
1990 2
1991 2
1992 1
1993 4
1994 2
1995 2
1996 4
1997 3
1998 3
1999 3
2000 7
2001 4
2002 3
2003 3
2004 4
2005 5
2006 6
2007 7
2008 11
2009 5
2010 6
2011 3
2012 7
2013 5
2014 17
2015 8
2016 3
2017 12
2018 12
2019 20
2020 16
2021 15
2022 9
2023 10
2024 5

Text availability

Article attribute

Article type

Publication date

Search Results

249 results

Results by year

Filters applied: . Clear all
Page 1
Chest Tube Drainage Devices.
Toth JW, Reed MF, Ventola LK. Toth JW, et al. Semin Respir Crit Care Med. 2019 Jun;40(3):386-393. doi: 10.1055/s-0039-1694769. Epub 2019 Sep 16. Semin Respir Crit Care Med. 2019. PMID: 31525813 Review.
The tube should be attached to a drainage system, such as one-, two-, or three-compartment devices, a one-way (Heimlich) valve for ambulatory drainage, a digital system, or a vacuum bottle. The frequently employed three-compartment systems, currently integrated disp …
The tube should be attached to a drainage system, such as one-, two-, or three-compartment devices, a one-way (Heimlich) valve for ambulator …
Safety and efficacy of vacuum bottle plus catheter for drainage of iatrogenic pneumothorax.
Chen SY, Kuo YW, Ho CC, Wu HD, Wang HC. Chen SY, et al. BMC Pulm Med. 2022 Jun 7;22(1):221. doi: 10.1186/s12890-022-02009-8. BMC Pulm Med. 2022. PMID: 35672758 Free PMC article. Clinical Trial.
RESULTS: From August 2018 to February 2020, 21 patients underwent vacuum bottle plus catheter drainage (intervention group) and 31 patients received conservative treatment (control group). ...Vacuum bottle assisted air drainage also help identifying pa …
RESULTS: From August 2018 to February 2020, 21 patients underwent vacuum bottle plus catheter drainage (intervention group) an …
Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.
Porcel JM. Porcel JM. Tuberc Respir Dis (Seoul). 2018 Apr;81(2):106-115. doi: 10.4046/trd.2017.0107. Epub 2018 Jan 24. Tuberc Respir Dis (Seoul). 2018. PMID: 29372629 Free PMC article. Review.
All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or grav …
All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural cat …
Vacuum assisted closure in coloproctology.
Bemelman WA. Bemelman WA. Tech Coloproctol. 2009 Dec;13(4):261-3. doi: 10.1007/s10151-009-0543-x. Epub 2009 Nov 12. Tech Coloproctol. 2009. PMID: 19907919 Free PMC article. Review.
Vacuum-assisted closure has earned its indications in coloproctology. ...The endosponge is inserted transanally and connected with a low vacuum bottle. With the gradual reduction in the cavity, the endosponge is reduced in size every 3-4 days when the endospo
Vacuum-assisted closure has earned its indications in coloproctology. ...The endosponge is inserted transanally and connected with a
Measurement of Phacoemulsification Vacuum Pressure in the Oertli CataRhex3.
Peterson JS, Cooper C, Ungricht EL, Mamalis C, Barlow W, Zaugg B, Bernhisel AA, Olson RJ, Pettey JH. Peterson JS, et al. Clin Ophthalmol. 2022 Jun 1;16:1731-1737. doi: 10.2147/OPTH.S356657. eCollection 2022. Clin Ophthalmol. 2022. PMID: 35673346 Free PMC article.
METHODS: The effective vacuum pressure created by the Oertli was measured with a pressure device that was continuous with the vacuum tubing system while closed to the external environment. Measurements were taken with the machine set to 300 and 500 mmHg at flow rate …
METHODS: The effective vacuum pressure created by the Oertli was measured with a pressure device that was continuous with the vacu
Thoracentesis techniques: A literature review.
Mohammed A, Hochfeld U, Hong S, Hosseini DK, Kim K, Omidvari K. Mohammed A, et al. Medicine (Baltimore). 2024 Jan 5;103(1):e36850. doi: 10.1097/MD.0000000000036850. Medicine (Baltimore). 2024. PMID: 38181250 Free PMC article. Review.
Thoracentesis is performed by 4 methods: gravity, manual aspiration, vacuum-bottle suction, and wall suction. This literature review investigates the safety of these techniques and determines if there is significant difference in complication rates. A comprehensive …
Thoracentesis is performed by 4 methods: gravity, manual aspiration, vacuum-bottle suction, and wall suction. This literature …
Suck-Swallow-Breathe Dynamics in Breastfed Infants.
Sakalidis VS, Geddes DT. Sakalidis VS, et al. J Hum Lact. 2016 May;32(2):201-11; quiz 393-5. doi: 10.1177/0890334415601093. Epub 2015 Aug 28. J Hum Lact. 2016. PMID: 26319112 Review.
Despite the importance of the suck-swallow-breathe reflex during breastfeeding, a large proportion of our understanding is derived from bottle-feeding studies. Given the differences in the delivery of milk during breast and bottle feeding, it is imperative that a mo …
Despite the importance of the suck-swallow-breathe reflex during breastfeeding, a large proportion of our understanding is derived from b
A controlled-flow vacuum-free bottle system enhances preterm infants' nutritive sucking skills.
Fucile S, Gisel E, Schanler RJ, Lau C. Fucile S, et al. Dysphagia. 2009 Jun;24(2):145-51. doi: 10.1007/s00455-008-9182-z. Epub 2008 Oct 4. Dysphagia. 2009. PMID: 18836778 Free PMC article. Clinical Trial.
We have shown that a controlled-flow vacuum-free bottle system (CFVFB) vs. a standard bottle (SB) facilitates overall transfer and rate of milk transfer, and shortens oral feeding duration in very-low-birth-weight (VLBW) infants. ...
We have shown that a controlled-flow vacuum-free bottle system (CFVFB) vs. a standard bottle (SB) facilitates overall t …
Comparative Recovery of Two Human Norovirus Surrogates, Feline Calicivirus and Murine Norovirus, with a Wet Vacuum System, Macrofoam-Tipped Swab, and Bottle Extraction Method from Carpets.
Buckley D, Fraser A, Pettigrew C, Anderson J, Jiang X. Buckley D, et al. J Food Prot. 2018 Jun;81(6):963-968. doi: 10.4315/0362-028X.JFP-17-518. J Food Prot. 2018. PMID: 29749764 Free article.
Currently, we lack virus recovery methods for soft surfaces, such as carpet, despite evidence suggesting that carpets contribute to HuNoV outbreaks. Our aim was to compare two recovery methods, wet vacuum and swabbing, for routine carpet sampling of HuNoV against a laborat …
Currently, we lack virus recovery methods for soft surfaces, such as carpet, despite evidence suggesting that carpets contribute to HuNoV ou …
Effect of vacuum-release teat versus standard teat use on feeding milestones and breastfeeding outcomes in very preterm infants: A randomized controlled trial.
Perrella SL, Nancarrow K, Trevenen M, Murray K, Geddes DT, Simmer KN. Perrella SL, et al. PLoS One. 2019 Mar 22;14(3):e0214091. doi: 10.1371/journal.pone.0214091. eCollection 2019. PLoS One. 2019. PMID: 30901356 Free PMC article. Clinical Trial.
Unlike standard bottle teats, a vacuum release teat requires the application of negative intra-oral pressure to release milk, and so may facilitate breastfeeding in preterm infants. ...Infants were randomized to one of two parallel groups using a vacuum relea …
Unlike standard bottle teats, a vacuum release teat requires the application of negative intra-oral pressure to release milk, …
249 results